Rebuilt Dryer Clean Press Shirt Sleeves Press Used
- Open the stop valve in the steam return line.
- Open the stop valve slowly, allowing the steam to gradually enter the press.
- When operating pressure is reached, open the press drain valve in the return line and drain the condensate into a bucket units steam flows freely. Then close the stop valve tightly.
- Open the air compressor.
open any air inlet valve to the press; check regulator for maximum 60psi.